Using the command line

Several executable parts of Antares_Simulator can be run in command line from a console. The list and general syntax of these components is given hereafter.

In all cases, arguments " –h" or "–help" can be used to get help

The solver executable : antares-8.3-solver

  • Simulation
command meaning
-i, --input Study folder
--expansion Force the simulation in expansion mode
--economy Force the simulation in economy mode
--adequacy Force the simulation in adequacy mode
--parallel Enable the parallel computation of MC years
--force-parallel=VALUE Override the max number of years computed simultaneously
  • Parameters
command meaning
-n, --name=VALUE Set the name of the new simulation to VALUE
-g, --generators-only Run the time-series generators only
-c, --comment-file=VALUE Specify the file to copy as comments of the simulation
-f, --force Ignore all warnings at loading
--no-output Do not write the results in the output folder
-z, --zip-output Force the write of results into a single zip archive
-y, --year=VALUE Override the number of MC years
--year-by-year Force the writing the result output for each year
(economy only)
--derated Force the derated mode
  • Optimization
command meaning
--optimization-range Force the simplex optimization range ('day' or 'week')
--no-constraints Ignore all binding constraints
--no-ts-import Do not import timeseries into the input folder.
(This option may be useful for running old studies without upgrade)
-m, --mps-export Export anonymous mps weekly or daily optimal UC+dispatch linear
-s, --named-mps-problems Export named mps weekly or daily optimal UC+dispatch linear
--solver-logs Print solver logs
  • Misc.
command meaning
--progress Display the progress of each task
-p, --pid=VALUE Specify the file where to write the process ID
-v, --version Print the version of the solver and exit
-h, --help Display this help and exit
--list-solvers Display a list of LP solvers available through OR-Tools and exit
--use-ortools --ortools-solver=Sirius Use the standard Antares solver through the OR-Tools modelling library
--use-ortools --ortools-solver=Coin Use the Coin solver through the OR-Tools modelling library

antares-8.3-study-updater

command meaning
-i, --input=VALUE Add an input folder where to look for studies
This argument is mandatory.
-c, --clean Clean all studies found
--remove-generated-timeseries Remove time-series which will be regenerated by
the ts-generators
-d, --dry List the study folders which may be upgraded and do nothing else
--force-readonly Force read-only mode for all studies found
-v, --version Print the version and exit
-h, --help Display this help and exit

antares-8.3-study-finder

command meaning
-i, --input=VALUE Add an input folder where to look for studies.
When no input folder is given, the current working dir is used.
-e, --extra Print the version of the study
--csv Print in a CSV format (semicolon)
-v, --version Print the version and exit
-h, --help Display this help and exit

antares-8.3-study-cleaner

command meaning
-i, --input=VALUE An input folder where to look for studies
--dry List the folder only and do nothing
--mrproper Suppress the outputs and logs files
-v, --version Print the version and exit
-h, --help Display this help and exit

antares-8.3-config

command meaning
-p, --print Print the current configuration
-v, --version Print the version and exit
-h, --help Display this help and exit

antares-8.3-batchrun

  • Studies
command meaning
-i, --input=VALUE The input folder, where to look for studies on which to run simulations
  • Simulation mode
command meaning
--expansion Force the simulation(s) in expansion mode
--economy Force the simulation(s) in economy mode
--adequacy Force the simulation(s) in adequacy mode
  • Parameters
command meaning
-n, --name=VALUE Set the name of the new simulation outputs
-y, --year=VALUE Override the number of MC years
-f, --force Ignore all warnings at loading
--no-output Do not write the results in the output folder
--year-by-year Force the writing of the result output for each year
  • Optimization
command meaning
--no-ts-import Do not import timeseries into the input folder.
--no-constraints Ignore all binding constraints
  • Extras
command meaning
--solver=VALUE Specify the antares-solver location
--parallel Enable the parallel computation of MC years
--force-parallel=VALUE Override the max number of years computed simultaneously
--verbose Display detailed logs for each simulation to run